Features and Applications
General Characteristics for GX-Series Subgrouping Cables
Standards List
Specifications - Riser | Plenum
Features and Applications
- Tight-buffered multifiber cable design allows subcables to be routed to multiple locations such as in wiring racks or wiring closets
- Core-LockedT outer jacket surrounds the subcables for excellent crush resistance, survivability, and use in long vertical installations
- Multifiber color-coded subcables, each similar to the DX-Series Distribution Cable
- Best design for multimode and single-mode fiber hybrid/composite cables (See part number note on page 24.)
- Color-coded subcables are easy to identify for improved cable management in routing and termination
- Helically stranded cable core for flexibility, survival in difficult pulls, and mechanical protection for the optical fibers
- Cable ideal for direct pulling with wire mesh grips
- High performance tight-buffered coating on each optical fiber for environmental and mechanical protection
- Suitable for both indoor and outdoor use -- no need to splice outdoor cable to indoor cable at the building entrance
- Flame-retardant for indoor installations
- Fungus-resistant, water-resistant, and UV-resistant for outdoor use
- Subgroup cables of GX-Series plenum cables are individually Plenum-rated and can be UL Plenum labeled
- 12 to 288 fibers in various subgroup cable sizes; higher fiber counts available upon request
- Water-blocked G-Series and GX-Series Subgrouping Cables are available
General Characteristics for GX-Series Subgrouping Cables
| |
Riser |
Plenum |
| Minimum Bend Radius: |
|
|
| Under Installation Tensile Load |
15X outside diameter |
15X outside diameter |
| Under Long-Term Tensile Load |
10X outside diameter |
15X outside diameter |
| Operating Temperature |
-40°C to +85°C |
-40°C to +85°C |
| Storage Temperature |
-55°C to +85°C |
-40°C to +85°C |
| Crush Resistance |
2,100 N/cm |
2,100 N/cm |
| Impact Resistance |
1,500 impacts |
1,500 impacts |
| Flex Resistance |
2,000 cycles |
2,000 cycles |
|
These specifications are subject to change without prior notification. |
Standards List
Optical Cable Corporation's indoor/outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:
- ANSI X3T9.5 PMD
- ATM 155 Mb/s
- FDDI 100 Mb/s
- Fibre Channel FC-PH
- GR-409-CORE
- ICEA-S-83-596
- TIA-568
- TIA-598-B
- TIA-758 (water-blocked cables)
UL-listed type OFNP in accordance with NEC sections 770-179 (A) and 770-154 (A) for use in ducts, plenums, and air-handling spaces. Meets or exceeds requirements for intra-building fiber optic cables as outlined in GR-409-CORE.
UL-listed type OFNR in accordance with NEC sections 770-179 (B) and 770-154 (B) for use in vertical runs in building riser shafts or from floor to floor. Meets or exceeds requirements for intra-building fiber optic cables as outlined in GR-409-CORE.
|